{"product_id":"18-3-shielded-wire-18-awg-3-conductor-plenum-cable-flexible","title":"18\/3 Shielded Wire 18 AWG 3 Conductor Plenum Cable - Flexible","description":"\u003cp\u003eIn this review of the 18\/3 Shielded Wire 18 AWG 3 Conductor Plenum Cable, the bottom line is simple: this cable is aimed at installers and system technicians who need a flexible, reliable shielded conductor for security, alarm and low-voltage audio work. The reviewer found its stranded pure copper cores and CMP plenum rating to be the strongest reasons to choose it, because they provide better conductivity than CCA and a flame-retardant jacket suitable for plenum spaces. For anyone running fire alarms, access control or public address wiring where fire performance and flexibility matter, this cable delivers.\u003c\/p\u003e\u003ch2\u003eKey Features\u003c\/h2\u003e\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eStranded pure copper:\u003c\/strong\u003e provides higher conductivity, lower resistance and better corrosion resistance than copper-clad alternatives to keep circuits reliable.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eShielded construction:\u003c\/strong\u003e reduces interference and helps protect sensitive alarm and communication signals in electrically noisy environments.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eCMP plenum-rated jacket:\u003c\/strong\u003e the flame-retardant CL3P\/CMP rating gives improved fire performance for installation in air-handling spaces.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eFlexible build:\u003c\/strong\u003e stranded conductor and pliable jacket make routing through conduit and around corners easier than solid-core wire.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eWide temperature range:\u003c\/strong\u003e rated for use from -10C\/14F to 90C\/194F, suitable for many indoor low-voltage installations.\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch2\u003eWho It's For\u003c\/h2\u003e\u003cp\u003eThis cable is well suited for professional installers and advanced DIYers wiring fire alarm systems, security burglar alarms, access control panels, intercoms and public address systems where signal integrity and plenum fire rating are required. It also fits applications like telephone stations, nurse call and low-voltage instrumentation that benefit from shielding and stranded copper conductors.\u003c\/p\u003e\u003cp\u003eIt is not aimed at high-voltage mains wiring or applications requiring single solid conductors for terminal blocks designed only for solid wire; users who need unshielded, cheaper general-purpose speaker cable or non-plenum cable for exterior burial should look elsewhere.\u003c\/p\u003e\u003ch2\u003ePros \u0026amp; Cons\u003c\/h2\u003e\u003cp\u003e\u003cstrong\u003ePros\u003c\/strong\u003e\u003c\/p\u003e\u003cul\u003e\n\u003cli\u003eStranded pure copper conductors deliver reliable conductivity and corrosion resistance for critical alarm circuits.\u003c\/li\u003e\n\u003cli\u003eCMP plenum-rated jacket offers enhanced fire safety for installations in plenum spaces.\u003c\/li\u003e\n\u003cli\u003eShielded design protects low-voltage communication signals from EMI in noisy environments.\u003c\/li\u003e\n\u003c\/ul\u003e\u003cp\u003e\u003cstrong\u003eCons\u003c\/strong\u003e\u003c\/p\u003e\u003cul\u003e\u003cli\u003eAvailable in a plenum jacket that is appropriate for indoor air-handling spaces but may be overkill for simple, non-plenum runs.\u003c\/li\u003e\u003c\/ul\u003e\u003ch2\u003eSpecifications\u003c\/h2\u003e\u003ctable\u003e\n\u003ctr\u003e\n\u003ctd\u003eConductor\u003c\/td\u003e\n\u003ctd\u003e18 AWG stranded pure copper\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eConductors\u003c\/td\u003e\n\u003ctd\u003e3 conductors\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eShielding\u003c\/td\u003e\n\u003ctd\u003eShielded\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eJacket rating\u003c\/td\u003e\n\u003ctd\u003eCMP \/ CL3P \/ FPLP (plenum-rated)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eLength\u003c\/td\u003e\n\u003ctd\u003e50 ft (product specification)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRated voltage\u003c\/td\u003e\n\u003ctd\u003e300 V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eTemperature range\u003c\/td\u003e\n\u003ctd\u003e-10C\/14F to 90C\/194F\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/table\u003e\u003ch2\u003eOur Verdict\u003c\/h2\u003e\u003cp\u003eThe 18\/3 Shielded 18 AWG plenum cable is a solid choice for anyone wiring alarms, access control or low-voltage audio where signal protection and plenum fire performance matter. Its stranded pure copper and shielding justify the use in commercial or residential plenum spaces, offering good value for installations that demand reliability and flame retardance.\u003c\/p\u003e\u003ch2\u003eFrequently Asked Questions\u003c\/h2\u003e\u003cp\u003e\u003cstrong\u003eIs this cable suitable for fire alarm systems?\u003c\/strong\u003e\u003cbr\u003eYes, it is designed for low-voltage alarm use and includes stranded pure copper conductors and shielding appropriate for many fire alarm installations.\u003c\/p\u003e\u003cp\u003e\u003cstrong\u003eCan this be used in plenum air-handling spaces?\u003c\/strong\u003e\u003cbr\u003eYes, the jacket carries a CMP\/CL3P\/FPLP plenum rating intended for installation in plenum spaces.\u003c\/p\u003e\u003cp\u003e\u003cstrong\u003eIs the conductor solid or stranded?\u003c\/strong\u003e\u003cbr\u003eThe product uses stranded pure copper conductors for flexibility and improved durability in routed runs.\u003c\/p\u003e","brand":"MOOKEERF","offers":[{"title":"Default Title","offer_id":48203745624283,"sku":"B0DT9HZ7RP","price":49.99,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0724\/1043\/1707\/files\/71cjFpOOyYL._SL1500.jpg?v=1770265673","url":"https:\/\/gearmusthave.com\/products\/18-3-shielded-wire-18-awg-3-conductor-plenum-cable-flexible","provider":"GearMustHave","version":"1.0","type":"link"}