{"product_id":"kvaser-memorator-pro-2xhs-v2-data-logger-and-usb-to-can-can-fd-dual","title":"Kvaser Memorator Pro 2xHS V2 Data Logger and USB-to-CAN\/CAN FD - Dual","description":"\u003cp\u003eIn this review the Kvaser Memorator Pro 2xHS v2 is presented as a professional dual channel CAN tool aimed at engineers and diagnostics specialists who need reliable simultaneous capture across two CAN buses. The bottom line: this device excels as a compact standalone data logger and a real time USB-to-CAN\/CAN FD interface, with the single biggest reason to buy being its ability to monitor and time synchronise two CAN channels simultaneously while offering galvanic isolation and CAN FD support.\u003c\/p\u003e\u003ch2\u003eKey Features\u003c\/h2\u003e\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eDual channel monitoring:\u003c\/strong\u003e Capture and compare traffic on two CAN buses at once using one device, simplifying multi-bus diagnostics and reducing bench clutter.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eCAN FD up to 8 Mbit\/s:\u003c\/strong\u003e Supports CAN FD speeds up to 8 Mbit\/s when the physical layer is implemented correctly, enabling higher-bandwidth message capture and modern ECUs testing.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eStandalone data logger:\u003c\/strong\u003e Uses an expandable SD card slot up to 64G so the unit can record long tests without a connected PC, making it suitable as a compact flight recorder for field work.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eGalvanic isolation:\u003c\/strong\u003e Isolated CAN bus drivers protect your test equipment and DUTs from ground loops and electrical noise during logging and live capture.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eFlexible power sources:\u003c\/strong\u003e Power may be supplied from USB, the CAN bus, or an in-built power supply option, which allows versatile deployment in bench and vehicle environments.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eScriptable with t-Program:\u003c\/strong\u003e Configurable via Kvaser Memorator Config Tool and capable of running user scripts in the t language for custom filtering, triggers, and automated actions.\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch2\u003eWho It's For\u003c\/h2\u003e\u003cp\u003eThe Memorator Pro 2xHS v2 is aimed at embedded systems engineers, automotive test technicians, and researchers who need deterministic, time-synchronised logging across two CAN networks or want a combined USB interface and logger in one compact package. Its support for CAN FD makes it appropriate for projects moving beyond classical CAN data rates.\u003c\/p\u003e\u003cp\u003eLess suitable users include hobbyists with only occasional single-bus needs or those who require an integrated graphical analysis suite bundled with the hardware; this is a professional-grade tool that assumes familiarity with CAN tooling and the Kvaser software ecosystem.\u003c\/p\u003e\u003ch2\u003ePros \u0026amp; Cons\u003c\/h2\u003e\u003cp\u003e\u003cstrong\u003ePros\u003c\/strong\u003e\u003c\/p\u003e\u003cul\u003e\n\u003cli\u003eSimultaneous dual channel capture with automatic time synchronisation simplifies comparative analysis between buses.\u003c\/li\u003e\n\u003cli\u003eSupports high-speed CAN FD up to 8 Mbit\/s, enabling modern ECU and sensor testing.\u003c\/li\u003e\n\u003cli\u003eStandalone logging with SD card support up to 64G provides long-duration recording without a PC.\u003c\/li\u003e\n\u003cli\u003eGalvanic isolation improves measurement safety and signal integrity in noisy environments.\u003c\/li\u003e\n\u003c\/ul\u003e\u003cp\u003e\u003cstrong\u003eCons\u003c\/strong\u003e\u003c\/p\u003e\u003cul\u003e\n\u003cli\u003eConfiguration and scripting require familiarity with Kvaser tools and the t programming language, which has a learning curve.\u003c\/li\u003e\n\u003cli\u003eThe unit relies on proper physical layer implementation to reach maximum CAN FD speeds, so installation details matter.\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch2\u003eSpecifications\u003c\/h2\u003e\u003ctable\u003e\n\u003ctr\u003e\n\u003ctd\u003eProduct\u003c\/td\u003e\n\u003ctd\u003eKvaser Memorator Pro 2xHS v2\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eChannels\u003c\/td\u003e\n\u003ctd\u003e2 CAN channels (simultaneous)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCAN standard\u003c\/td\u003e\n\u003ctd\u003eCAN and CAN FD (up to 8 Mbit\/s with proper physical layer)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePower\u003c\/td\u003e\n\u003ctd\u003eUSB, CAN power, or built-in power supply option\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eIsolation\u003c\/td\u003e\n\u003ctd\u003eGalvanically isolated CAN bus drivers\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eStorage\u003c\/td\u003e\n\u003ctd\u003eExpandable SD card slot up to 64G\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eConfig \u0026amp; scripting\u003c\/td\u003e\n\u003ctd\u003eKvaser Memorator Config Tool and t programming language\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/table\u003e\u003ch2\u003eOur Verdict\u003c\/h2\u003e\u003cp\u003eThe Kvaser Memorator Pro 2xHS v2 is a well-engineered, professional dual channel CAN logger and USB interface that delivers precise time-synchronised captures and CAN FD support in a compact package. Engineers who need robust, long-duration logging and safe, isolated bus connections will find it excellent value for field and bench diagnostics, provided they are comfortable using Kvaser configuration tools and scripting.\u003c\/p\u003e\u003ch2\u003eFrequently Asked Questions\u003c\/h2\u003e\u003cp\u003e\u003cstrong\u003eCan this unit record without a PC?\u003c\/strong\u003e\u003cbr\u003eYes. It functions as a standalone data logger using the onboard SD card slot up to 64G for long recordings.\u003c\/p\u003e\u003cp\u003e\u003cstrong\u003eDoes it support CAN FD speeds reliably?\u003c\/strong\u003e\u003cbr\u003eYes, it supports CAN FD up to 8 Mbit\/s when the physical layer and cabling are implemented correctly.\u003c\/p\u003e\u003cp\u003e\u003cstrong\u003eHow is the device powered?\u003c\/strong\u003e\u003cbr\u003ePower can come from the USB connection, from the CAN bus, or from an available built-in power supply option.\u003c\/p\u003e","brand":"Kvaser","offers":[{"title":"Default Title","offer_id":48741233393883,"sku":"B07N1W32L8","price":1427.95,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0724\/1043\/1707\/files\/31av8Yh8ITL.jpg?v=1778926085","url":"https:\/\/gearmusthave.com\/products\/kvaser-memorator-pro-2xhs-v2-data-logger-and-usb-to-can-can-fd-dual","provider":"GearMustHave","version":"1.0","type":"link"}